{"id":10181,"date":"2017-07-04T14:51:28","date_gmt":"2017-07-04T09:21:28","guid":{"rendered":"http:\/\/newmeditech.com\/?p=10181"},"modified":"2017-07-04T14:56:27","modified_gmt":"2017-07-04T09:26:27","slug":"digital-student-physiograph","status":"publish","type":"post","link":"http:\/\/newmeditech.com\/secure\/products\/lab-equipments-products\/physiology\/digital-student-physiograph\/","title":{"rendered":"Digital Student Physiograph"},"content":{"rendered":"
Meditech Technologies India Pvt. Ltd is the largest manufacturer and exporter of\u00a0 Digital Student Physiograph.<\/p>\n
Meditech Technologies\u2019s STUDENT PHYSIOGRAPH recorder is a highly sensitivity oscillograph mainly being used for teaching experiment physiology and pharmacology. The design concept is so that it is easily understood by the student at undergraduate and post graduate levels.<\/p>\n
<\/p>\n
<\/p>\n
Features<\/b><\/p>\n STUDENT PHYSIOGRAPH Comprises Of<\/b><\/p>\n Couplers<\/b><\/p>\n To record different parameters the standard range of couplers are as follows<\/p>\n a)Biopotential<\/b> Coupler:<\/b> Meditech\u2019s Bio-Potential coupler is designed to record almost all kinds of AC Phenomena like ECG, EEG, EMG, ERG or any other A.C. Phenomenon.<\/p>\n b)EKG <\/b>Coupler:<\/b> The EKG coupler provides a convenient means of recording the input of five electrodes in various combinations. For Recording Clinical EKG It is Supplied With 5 Pin Junction Box, Limb & Chest Electrodes & Jelly<\/p>\n c)Strain <\/b>Gage Coupler:<\/b> Coupler for recording from all Meditech’s Strain Gage Transducers. & Use to record muscle activity force , effect of Drug on heart activity etc<\/p>\n d)Pulse- <\/b>Respiration Couplers:<\/b> For recording Pulse or respiration using Photo-electric transducers.<\/p>\n e)Temperature <\/b>Coupler:<\/b> for recording internal or surface temperature through Meditech’s temperature transducer<\/p>\n f)Isotonic <\/b>Coupler:<\/b> for recording with Isotonic Fine movement transducer.<\/p>\n \t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/p>\n Transducers<\/b><\/p>\n A transducer is a device which converts one form of physical energy to electrical energy or vice versa. To record parameter which are not available in electrical form e.g. Pulse, Respiration, Temperature ,Phono Cardiogram etc., one need to use appropriate transducer.<\/p>\n \t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/p>\n \t\t<\/div>\r\n\t<\/div>\r\n<\/div><\/p>\n\n
Couplers<\/h4>\r\n\t\t\t\t
Transducers<\/h4>\r\n\t\t\t\t
\n\n
\n Specifications<\/td>\n Models<\/td>\n<\/tr>\n \n PHYSIO-1<\/td>\n PHYSIO-2<\/td>\n PHYSIO-3<\/td>\n<\/tr>\n \n No. of Channels<\/td>\n 1<\/td>\n 2<\/td>\n 3<\/td>\n<\/tr>\n \n Display<\/td>\n TFT Display<\/td>\n<\/tr>\n \n Display Size<\/td>\n 15.5 cm \u00d7 9.5 cm<\/td>\n<\/tr>\n \n Channel Width<\/td>\n 80 mm<\/td>\n<\/tr>\n \n A\/D Conversion<\/td>\n 16 bit A\/D<\/td>\n<\/tr>\n \n Sensitivity<\/td>\n 50,100,200,500 uv\/cm and
\n1,2,5,10,20,50,100 mv\/cm<\/td>\n<\/tr>\n\n Sweep Speed<\/td>\n 0.05,0.1,0.2,0.5,1,2,5,10,20,50 & 100 div\/sec<\/td>\n<\/tr>\n \n Data Sampling Frequency<\/td>\n >256 Hz<\/td>\n<\/tr>\n \n Notch Filter<\/td>\n 50 to 60 Hz<\/td>\n<\/tr>\n \n Input Impendence<\/td>\n >1 Mega Ohm<\/td>\n<\/tr>\n \n CMRR<\/td>\n >80 \u2013 85 db<\/td>\n<\/tr>\n \n Power Supply Requirements<\/td>\n 220\/230V AC 50Hz 110\/120V AC 50-60Hz*<\/td>\n<\/tr>\n \n Certification<\/td>\n CE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n Standard Accessories<\/h4>\r\n\t\t\t\t
\n\n
\n ECG Electrodes<\/td>\n 1 Set of 4 Nos.<\/td>\n<\/tr>\n \n EEG Electrodes<\/td>\n 10 Nos.<\/td>\n<\/tr>\n \n Bio-Potential Junction Box<\/td>\n 1 No.<\/td>\n<\/tr>\n \n EG Disc Electrodes<\/td>\n 1 Set of 10 Nos.<\/td>\n<\/tr>\n \n Ground Electrode<\/td>\n 1 No.<\/td>\n<\/tr>\n \n EEG Paste<\/td>\n 1 Jar<\/td>\n<\/tr>\n \n ECG Jelly<\/td>\n 1 Bottle<\/td>\n<\/tr>\n \n Operating Manual<\/td>\n 1 No.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n