{"id":3857,"date":"2013-01-27T12:32:19","date_gmt":"2013-01-27T07:02:19","guid":{"rendered":"http:\/\/newmeditech.com\/?p=3857"},"modified":"2018-03-30T15:06:58","modified_gmt":"2018-03-30T09:36:58","slug":"plant-growth-chamber-mtr26","status":"publish","type":"post","link":"https:\/\/newmeditech.com\/secure\/plant-growth-chamber\/plant-growth-chamber-mtr26\/","title":{"rendered":"Plant Growth Chamber MTR26"},"content":{"rendered":"

Plant Growth Chamber MTR26<\/span><\/h2>\n

Plant Growth Chamber\u00a0Product Description<\/span><\/h3>\n

The Plant Growth Chamber MTR26 provides 26ft2<\/sup> (2.4m2<\/sup>)of growth area and 24\u201d (610mm) of growth height over two shelves. Plant Growth Chamber is suitable for a range of applications including the growth of short to medium height plants that require moderate light intensity. Standard is a closed-loop lighting system. The\u00a0Plant Growth Chamber is shipped fully assembled, fits through standard doorways, and has a low overall height for confined ceiling spaces. Please consult Meditech with your particular application and area of research and we will provide you with an overview of the available options for Plant Growth Chamber<\/span><\/p>\n

\r\n\t\t\t\t\t
Download Plant Growth Chamber Catalog<\/span><\/a>inquire<\/span><\/a><\/div><\/div><\/span><\/p>\n

 <\/p>\n\n\n\n\n\n\n\n\n\n\n\n\n
Specification Of Plant Growth Chamber MTR26
\n<\/span><\/th>\n<\/tr>\n<\/thead>\n
Temperature Range<\/span><\/th>\n +10\u00b0C to +45\u00b0C lights on<\/strong><\/span><\/td>\n<\/tr>\n
Growth Area<\/span><\/th>\n26ft2 (2.4m2)<\/strong><\/strong><\/span><\/td>\n<\/tr>\n
Growth Height
\n<\/span><\/th>\n
24\u201d (610mm)\u00a0Plant Growth Chamber
\n<\/strong><\/span><\/td>\n<\/tr>\n
External Dimensions<\/span><\/th>\n94.5\u201d x 35\u201d x 78\u201d (2415mm x 890mm x 1980mm)
\n<\/strong><\/span><\/td>\n<\/tr>\n
Internal Capacity<\/span><\/th>\n26ft3 (736l)
\n<\/strong><\/span><\/td>\n<\/tr>\n
Electrical Service <\/span><\/th>\n120\/208-3\u00d8-60Hz <\/strong><\/span>(220\/380-3\u00d8-50Hz)<\/strong><\/span><\/span><\/td>\n<\/tr>\n
Light Intensity<\/span><\/th>\n600 \u03bcmoles\/m2\/s
\n<\/strong><\/span><\/td>\n<\/tr>\n
Weight<\/strong>
\n<\/span><\/th>\n
1325lb (601kg)
\n<\/strong><\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

\"\"<\/a>\"\"<\/a>\"\"<\/a><\/span><\/h3>\n

<\/h3>\n

<\/h3>\n

<\/h3>\n

 <\/p>\n

<\/h3>\n

<\/h3>\n

<\/h3>\n

<\/h3>\n

Plant Growth Chamber Product Overview\/Applications<\/span><\/h3>\n

The Plant Growth Chamber MTR26 provides 26ft2 (2.4 m2) of growth area and 24\u201d (610mm) of growth height over two shelves and is suitable for a range of applications including the growth of short to medium height plants that require moderate light intensity. Standard is a closed-loop lighting system. The chamber is shipped fully assembled, fits through standard doorways, and has a low overall height for confined ceiling spaces. Please consult Meditech with your particular application and area of research and we will provide you with an overview of the available options.<\/span><\/p>\n

Plant Growth Chamber – Lighting<\/span><\/h3>\n

The standard lighting system of\u00a0Plant Growth Chamber uses both T8 fluorescent and halogen incandescent lamps resulting in a broad based lighting spectrum. Also standard is a closed-loop lighting system (programmed in micro moles) which allows for precise and repeatable control of light output while also automatically adjusting for lumen maintenance. Light intensity of\u00a0Plant Growth Chamber is 600 micromoles\/m2\/s which is measured by a quantum light meter and transmitted to the controller for user readout. Lamp heat is controlled and managed by the refrigeration system in Plant Growth Chamber<\/span><\/p>\n

Airflow – Plant Growth Chamber<\/span><\/h3>\n

Airflow inside the Plant Growth Chamber is distributed to the two shelves through two Meditech Uni-floor systems \u2013 one at the floor level and another just below the second shelf. The air is discharged upward resulting in uniform air distribution throughout the growth area of Plant Growth Chamber. The unit includes fresh air intake and exhaust ports which are adjustable to allow up to 20 ft3\/min (0.57m3\/min.) of air exchange.<\/span><\/p>\n

\u00a0Refrigeration<\/span><\/h3>\n

Cooling for\u00a0Plant Growth Chamber is provided by a self-contained water-cooled condensing unit with hot gas bypass for continuous compressor operation. An electronic modulating valve provides tight temperature control while ensuring quiet operation. Pressure transducers are included for monitoring the status of the refrigeration system in Plant Growth Chamber. Alternative refrigeration methods are available depending on site-specific and\/or user-defined requirements Consult the factory for heat rejection information and other refrigeration options for Plant Growth Chamber<\/span><\/p>\n

Experiment Protection<\/span><\/h3>\n

User programmable \u201cset and forget\u201d alarms track the chamber\u2019s operation versus user-defined set points. This allows for exceptionally accurate monitoring without the need for adjustment every time the set point is redefined. Backup \u201chigh\/ low\u201d alarms provide a further level of protection while visual and audible notification is provided when any alarm is activated in Plant Growth Chamber. Contacts for connection to a building management system are also included.<\/span><\/p>\n

Key Product Attributes – Plant Growth Chamber<\/strong><\/span><\/h3>\n

\u2022 26 square feet (2.4 m2) growth area over two shelves for short to medium height plants<\/span>
\n \u2022 Shipped fully assembled \u2013 fits through standard doorways<\/span>
\n \u2022 Closed-loop light control with dimming ballasts in Plant Growth Chamber<\/span>
\n \u2022 Product certifications\/markings; CE<\/span><\/p>\n

 <\/p>\n

 <\/p>\n","protected":false},"excerpt":{"rendered":"

Plant Growth Chamber MTR26 Plant Growth Chamber\u00a0Product Description The Plant Growth Chamber MTR26 provides 26ft2 (2.4m2)of growth area and 24\u201d (610mm) of growth height over two shelves. Plant Growth Chamber is suitable for a range of applications including the growth of short to medium height plants that require moderate light intensity. Standard is a closed-loop […]<\/p>\n","protected":false},"author":1,"featured_media":10446,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[410],"tags":[411,412,413,426],"aioseo_notices":[],"yoast_head":"\nPlant Growth Chamber<\/title>\n<meta name=\"description\" content=\"(1) Plant Growth chamber for growing Plants (2) 7 " Touch Screen Controller (3) state-of-the-art technology and compact unit (4) CE\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/newmeditech.com\/secure\/plant-growth-chamber\/plant-growth-chamber-mtr26\/\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Plant Growth Chamber","description":"(1) Plant Growth chamber for growing Plants (2) 7 \" Touch Screen Controller (3) state-of-the-art technology and compact unit (4) CE","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"http:\/\/newmeditech.com\/secure\/plant-growth-chamber\/plant-growth-chamber-mtr26\/"},"_links":{"self":[{"href":"https:\/\/newmeditech.com\/secure\/wp-json\/wp\/v2\/posts\/3857"}],"collection":[{"href":"https:\/\/newmeditech.com\/secure\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/newmeditech.com\/secure\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/newmeditech.com\/secure\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/newmeditech.com\/secure\/wp-json\/wp\/v2\/comments?post=3857"}],"version-history":[{"count":2,"href":"https:\/\/newmeditech.com\/secure\/wp-json\/wp\/v2\/posts\/3857\/revisions"}],"predecessor-version":[{"id":10448,"href":"https:\/\/newmeditech.com\/secure\/wp-json\/wp\/v2\/posts\/3857\/revisions\/10448"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/newmeditech.com\/secure\/wp-json\/wp\/v2\/media\/10446"}],"wp:attachment":[{"href":"https:\/\/newmeditech.com\/secure\/wp-json\/wp\/v2\/media?parent=3857"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/newmeditech.com\/secure\/wp-json\/wp\/v2\/categories?post=3857"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/newmeditech.com\/secure\/wp-json\/wp\/v2\/tags?post=3857"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}