    Ice Lined Refrigerator – 340 liters MTBBR4

    Meditech ice lined refrigerator minimizes thermal shock. Vaccines are damaged due to sudden exposure of power outage. Due this vaccines are subjected to temperature change.Meditech assures to supply ice lined refrigerators to overcome high and low temperatures issues by providing temperature alarms. Meditech PLC based controllers limit the variation in temperatures in the cabinet to less than 1 degree C.

    Ice lined refrigerator ensures that there is no freezing inside the vaccine compartment during cold chain operation. There is almost 40% power save with Meditech PLC technology. very less current is consumed to keep vaccines for more than 24 Hours.

    Meditech helps in storing life saving vaccines which can cause million of dollars. Thousands of lives are dependent on these vaccines on daily basis.Meditech ice line refrigerators performs in the most adverse condition for more than 50 degree C. Therefore it makes sense to invest in better technology for better results.

    Ice Lined Refrigerator 340 litres features

    Reliable temperature between +2°C to +8°COnly 8 hrs. of electricity needed per 24 hrs. at 43°C AMBSelf-regulating cooling system
    Air flow system in vaccine compartmentExternal cabinet and internal liner pre-painted galvanized steelCooling coil of copper
    CFC-free refrigerant and insulationCompressor made for use in the tropicsSolid lid with handle and lock
    7 baskets for organized storageAvailable in 220V-240V 50/60Hz + 115V 60HzDelivered in solid, wooden crate

    PLC Based Controller

    LIVE Data logger
    LED INDICATIONUser Friendly Settings
    1.Temperature
    1.Line In
    1.Date
    2.Incoming Voltage
    2.Power
    2.Time
    3.Ambient Temperature
    3.Comp On
    3.High Temp Alarm
    4.Time in hours of revolution chart
    4.Heater On
    4. Low Temp Alarm
    5.Current Date
    5.Battery On5. Hysteresis
    6.Current Time
    6.Battery Low6. Compressor Delay
    7.Battery Voltage
    7.Temperature High
    8.Temperature Low
    9.Sensor Fail
    10.Power Fail
    11.Chart Change
    12.System On
    Gross volume, litres(cu. ft.)340 (12.0)
    Net volume, litres (cu. ft.)211 (7.4)
    Temperature range, C°+2 to +8
    Hold-over time during power cut at 43°C AMB, hrs25.66
    Power consumption per 24h, kWh2.13
    RefrigerantR134a
    No. of baskets7
    Height, mm (inches)645(25.4)
    Width, mm (inches)415(16.3)
    Depth, mm (inches)855(33.7)
    Gross weight, kg (lbs)335.1/399.0
    Net weight, kg (lbs)152/181
    Qty. per 20' container18
    Qty. per 40 container42
    Catalog
    Manual
    Spare Parts

    Ice Lined Refrigerator – Model Selection Guide

    ModelGross VolumeheightwidthDepthpower
    per 24 hrs
    MTBBR1

    64 Ltrs, 2.3 Cu ft840 (33.1) 720 (28.3)700 (27.6)2.30 kWH
    MTBBR2


    136 ltrs, 4.8 Cu ft840 (33.1) 700 (27.6)920 (36.2) 1.89 kWH
    MTBBR3

    218 ltrs, 7.7 Cu Ft840 (33.1)700 (27.6)1260 (49.6) 3.20 kWH
    MTBBR4

    340 ltrs, 12.0 Cu ft650(25.6)1650(65.0)855(33.7)2.13 kWH