Tissue Culture Chamber MTC80 is specifically designed for the growth of tissue culture. With four shelves and a top-mounted refrigeration system, the Tissue Culture Chamber TC80 provides an exceptional growth area-to-footprint ratio. The four shelves channel the airflow upward which acts to minimize the formation of condensation inside the lids of Petri dishes and other tissue culture vessels. Please consult Meditech regarding specific requirements for Tissue Culture Chamber.
Specification Of Tissue Culture Chamber MTC80 | |
---|---|
Temperature Range | +10°C to +45°C lights on |
Growth Area | 76ft2 (7.06m2) |
Growth Height |
12” (305mm) Tissue Culture Chamber |
External Dimensions | 100” x 35.5” x 106” (2540mm x 900mm x 2565mm) |
Internal Capacity | 20ft3 (566l) |
Electrical Service | 120/208-3Ø-60Hz (220/380-3Ø-50Hz) |
Light Intensity | 200 μmoles/m2/s |
Weight | 2115lb (960kg) |
Product Overview/Applications
The Tissue Culture Chamber MTC80 is specifically designed for the growth of tissue culture. With four shelves and a top-mounted refrigeration system, the Tissue Culture Chamber MTC80 provides an unprecedented growth area-to foot print ratio. The four shelves channel the airflow upward which acts to minimize the formation of condensation inside the lids of Petri dishes and other tissue culture vessels. Please consult Meditech regarding specific requirements Tissue Culture Chamber.
Lighting – Tissue Culture Chamber
Standard lighting for the Tissue Culture Chamber MTC80 is energy efficient fluorescent lamps. The lamps are separated from the growth area by a transparent barrier which minimizes heat transfer to the growing cultures. Lamp and ballast heat are controlled and managed by the refrigeration system. Lighting control provides three light levels and is monitored by a quantum light meter and displayed in micromoles/m²/s on the controller’s status screen for user readout.
Airflow – Tissue Culture Chamber
Airflow is distributed uniformly upward from each air shelf which helps to ensure a consistent temperature zone over each shelf Tissue Culture Chamber. Filtered and adjustable fresh air intake and exhaust openings enable researchers to exchange air to the chamber in a controlled manner up to 20ft3/min (0.57m3/min.) in Tissue Culture Chamber.
Refrigeration – Tissue Culture Chamber
Cooling for the Tissue Culture Chamber MTC80 is provided by a top mounted water cooled condensing unit with hot gas bypass for continuous compressor operation. Tissue Culture Chamber An electronic modulating valve provides tight temperature control while ensuring quiet operation. Pressure transducers are included for monitoring the status of the refrigeration system. Alternative refrigeration methods are available depending on site-specific and/or user-defined requirements Consult the factory for heat rejection Information and other options for cooling
Experiment Protection – Tissue Culture Chamber
User programmable “set and forget” alarms track the chamber’s operation versus user-defined set points Tissue Culture Chamber. This allows for exceptionally accurate monitoring without the need for adjustment every time the set point is redefined in Tissue Culture Chamber. Backup “high/low” alarms provide a further level of protection while visual and audible notification is provided when any alarm is activated. Contacts for connection to a building management system are also included.
Key Product Attributes – Tissue Culture Chamber
• Four conditioned shelves providing 80 ft2 of culture area in a small footprint
• Small footprint relative to growth area in Tissue Culture Chamber
• Top-mounted machine compartment minimizes footprint, accommodates serviceability, and simplifies installation
• Upward airflow through each shelf to minimize the formation of condensation on vessels
• Tissue Culture Chamber Product certifications/markings : CE